Low Voltage Motors
Current Location
: Home > Electric Motor > Low Voltage Motors

BPY General-Purpose VSD Three-Phase Asynchronous Motor
Product Overview
product
Electric MotorThe BPY series is a general-purpose, variable-speed drive (VSD) compatible three-phase squirrel-cage asynchronous motor, designed and manufactured to national standards. It is suitable for both variable-frequency drive (VSD) operation and direct-on-line (DOL) starting. The motor features an optimized electromagnetic design and modern manufacturing processes to balance high efficiency and a wide speed range. Key advantages include high starting torque, stable speed control, low noise, low vibration, and reliable operation. The BPY series is widely used for fans, pumps, compressors, conveyors, rolling mills, test rigs and other industrial equipment requiring VSD. Typical application sectors include power, metallurgy, mining, petrochemical, water conservancy, building materials, marine, nuclear power, and municipal engineering.
Main technical highlights:
Standard design & interchangeability: Standard mounting and dimensions per national GB/T standards, facilitating interchange and field replacement.
Optimized for VSD: Electromagnetic design optimized for VSD operation across a wide frequency range (5–100 Hz), ensuring good starting torque and stable low-frequency control.
Cooling & protection: Cooling methods IC411 (self-ventilated) or IC416 (forced ventilation) to suit different heat-dissipation and continuous-duty requirements. Standard protection rating IP55, upgradable to IP56/IP65 on request.
Insulation & thermal rating: F-class insulation designed to meet B-class temperature-rise evaluation, offering improved thermal and aging resistance.
Frame / power / poles: Frame sizes 80–450; rated power range 0.75 kW – 900 kW; poles 2P/4P/6P/8P/10P; rated voltage 380 V / 660 V; rated frequency 50 Hz (VSD support 5–100 Hz).
Bearings & lubrication: Frames ≤225 use sealed bearings; frames >225 use re-lubrication bearings or oil-bath lubrication as configured for power and duty. Suitable for long continuous operation.
Terminal box & monitoring: Top-mounted terminal box with left/right exit options. Optional PT100 / thermal sensors, speed encoders, and insulation monitoring devices.
EMC & VSD compatibility: Robust electromagnetic compatibility and anti-interference design to suit common inverter drives. For extended motor life, use output filters and cable shielding as recommended in VSD systems.
Quality & testing: Strict process control and factory testing including dynamic balancing, insulation tests, no-load/load tests, noise & vibration checks, and temperature-rise tests to ensure stable performance at delivery.
| Item | Parameter |
|---|---|
| Frame Size | 80 – 450 |
| Rated Power | 0.75 kW – 900 kW |
| Number of Poles | 2P / 4P / 6P / 8P / 10P |
| Rated Frequency (rated / VSD) | 50 Hz (supports 5–100 Hz VSD operation) |
| Rated Voltage | 380 V / 660 V (customizable per customer request) |
| Efficiency Class | Compliant with national high-efficiency levels (can meet IE2 / IE3 / national Level 2 upon request) |
| Protection Class | IP55 (optional IP56 / IP65) |
| Cooling Method | IC411 / IC416 (configurable) |
| Insulation & Temp. Rise | Insulation class F (designed to B-class temperature-rise evaluation) |
| Mounting | Horizontal / Vertical (flange mounting options available) |
| Applicable Drive Modes | DOL (Direct On Line) / VSD (Variable Speed Drive) |
Operating Conditions
Ambient temperature: −15 °C to +40 °C
Relative humidity: ≤ 90% (at 20 °C)
Altitude: ≤ 1000 m (higher-altitude designs available on request)
BPY series is recommended for applications requiring VSD or frequent start-stop cycles — especially fans, pumps, air compressors, conveyors, rolling lines, flying shears, and test benches. Selection guidance:
For constant-torque VSD loads (e.g., conveyors, compressors), choose a VSD-matched motor and pair with a suitable inverter and output filter.
For long continuous heavy loads or high starting-torque requirements, consider upsizing one power class and use reinforced bearing lubrication or oil-film lubrication.
For outdoor or humid environments, select higher protection (IP65) and anti-corrosion / moisture-resistant treatments.
For EMC-sensitive installations, install motor-side output filters and cable termination suppression when using long cable runs.
Before shipment, each motor undergoes comprehensive inspections and acceptance tests: mechanical appearance check, dynamic balance test, insulation resistance and dielectric tests, no-load and (if required) load tests, noise and vibration checks, and temperature-rise tests. A factory certificate, inspection report, wiring diagram, and maintenance manual are supplied with the motor.

(product image placeholder)
When placing an order, please specify: motor model, frame size, rated power, number of poles, rated voltage, cooling method (IC411 / IC416), mounting orientation (horizontal / vertical), whether protection upgrade is required (IP56 / IP65), and whether temperature sensors or other monitoring devices are needed. For special service conditions (high altitude, high temperature, strong corrosion, etc.), please provide detailed operating conditions so we can perform dedicated design and quoting.